Wednesday, December 9, 2009

Read All About It!

Energy Imaging's 3 page feature story in B2B in Canberra (business and government) magazine is 'live' on the web.

You can view the article at the following address (best viewed in full screen mode - top left corner):

They were distributed to Canberra businesses and government agencies yesterday so keep an eye out for a hard copy if you are in the national capital!

Tuesday, December 1, 2009

Watch All About It!

Watch an Energy Imaging air leakage and insulation assessment in action. Hands-on Directors, Jenny Edwards and Andrew Cleary, use their fan depressurisation and thermal imaging technologies to find all the concealed areas of energy loss in a home.

www.youtube.com/watch?v=auACO5rTgI8

Friday, November 20, 2009

Spend summer swimming for a sustainable future!

Energy Imaging, and our good friends at Graphic Ark, are proudly supporting Swim for Solar in the Canberra/Queanbeyan region this summer. This great initiative will be launched at 4.30 pm on Friday 27th November at Queanbeyan Pool. Come along and see the Energy Imaging team challenge the politicians, Mike Kelly and Shane Rattenbury, to a swim-off!

LifeSaving Energy Swims for Solar is a community project to raise funds to install solar panels on community buildings. The project is an initiative of Clean Energy for Eternity (CEFE).

People of all ages and swimming ability can join in the fun. Jump in the pool to stay cool this summer and help capture those rays to reduce your community's carbon footprint!

CEFE is a not-for-profit group which aims to inspire local community action on climate change. CEFE began in Bega in 2006 and each year runs the LifeSaving Energy Big Swims. So far the swims have raised over $60,000 to install solar panels and wind turbines on surf lifesaving clubs, fire brigades and community buildings in NSW.

Check to see if your local pool is involved. If not encourage them to do so. For more info click here

Sunday, October 18, 2009

Canberra's sustainable (& unsuckable) house!

Nick Mayo and Sarah Clayton live independently of water and power services in the heart of Canberra. Their home, in Duffy Street Ainslie, is a truly sustainable house with all sorts of clever, and great looking, features. For example, look carefully at the second and fourth window in the picture above and you’ll see a glazed brick wall - a very clever and stylish use of thermal mass.

Our infrared imaging of the building envelope confirmed that this is a house with outstanding thermal performance (the image below shows the internal surface of the glazed wall, pointed out above). Better still, when we conducted an air leakage test and tried to suck air out of the home we found it to be the most tightly constructed property we have ever tested. An airtight and well insulated building envelope is the most important thing for building comfort, energy efficiency and durability: this home experiences very little conductive or convective heat loss/gain and will most certainly stand the test of time. Very impressive!

Wednesday, July 8, 2009

Grand - Air-Tight - Designs

The episode of Grand Designs that went to air on ABC 1 last night featured a new home "built using the latest avant garde eco technologies." On top of its eco-concrete foundations sit a series of timber frame boxes, heavily insulated with recycled newspaper and clad in English cedar. Large, triple glazed windows to the south help to heat the house using the power of the sun to warm the heavy concrete slab. To conserve heat the whole building was: enveloped in a special membrane to make it super-airtight; tested using the same air leakage assessment technology that Energy Imaging use; and then fitted with a ventilation system to recover heat from the air.

The UK building codes of 2006 introduced mandatory air leakage testing of new houses. Best practice for building air leakage is considered to be between 3 and 7 m3 of air, per hour, per m2 of permeable surafce area at a 50 Pascal (Pa) pressure difference between inside and out. Once a building gets below 3 at 50 Pa, mechanical ventilation is required to maintain indoor air quality. The home featured on Grand Designs achieved an impressive score of just 1.2. To put this into perspective, most houses we test in Canberra are between 15 and 25 at 50 Pa!

Australia is yet to introduce a maximum air leakage standard for new buildings despite it being the most cost effective way to achieve direct energy savings, reduce GHG emissions and improve comfort levels. It is also the simplest and most cost-effective way to retrofit an existing building.

NB: there is a difference between insulation and air leakage. Insulation does not prevent air leakage. Both insulation and air leakage must be addressed to achieve energy efficeincy. Your insulation cannot do its job if your precious heated air can escape directly through holes in the buidling envelope. If you are serious about improving the energy efficiency of your home: 1. seal the air leaks + 2. insulate thoroughly and evenly... 1 + 2 = 3 x more efficient heating in your average Canberra home.

Cool Lights!

50W halogen downlights have been hot stuff in the world of lighting for far too long - see an earlier blog for our thoughts on halogen downlights. Fortunately, there are some cool new alternatives, such as unvented 8W LEDs. See just how hot and just how cool below!

We decided to make a direct comparison and installed a 5W LED in place of one of five 50W halogens in a kitchen. The old halogen globe, light fitting and transformer were quickly and simply removed and the LED was installed directly into the existing hole in the gyprock (sometimes it can be a little trickier depending on the wiring set up).

The result is impressive - the new LED (on the right, above) is very bright and it casts a broader and more even light than the halogens. This kitchen will only need 3-4 LEDs (rather tha 5 halogens) that's a reduction from 250W to 24-32W!
Most impressive was the temperature difference. The lights were switched on at the same time and in less than 5 minutes the halogen was at 98 degrees and the LED was just 16 degrees! The LED is barely visible on the right hand side of the thermal image above. See below for close ups.
The LEDs not only reduce your lighting energy-use and fire risk, but because they are a completely sealed unit they prevent any air leakage (and they can be insulated over because they are so cool), significantly reducing heat loss... and therefore even more energy use!

You can read more about this partiuclar LED here.

Wednesday, June 3, 2009

Enviro Expo 12-13 June

Story from p20, Canberra City News May 28-June 3.
Energy Imaging and more than 30 other businesses/groups with a sustainability focus will be exhibiting at a free two-day Enviro Expo at the Queanbeyan Conference Centre as Queanbeyan City Council celebrates World Environment Day 2009.

The Expo, to be held on Friday June 12 and Saturday June 13, will showcase ways that the local community can reduce its impact and the environment.

Download a flyer and program of events here.